If first inode item is missing, lowmem check will detect it but not output any error message.
Add error message for it. Signed-off-by: Qu Wenruo <quwen...@cn.fujitsu.com> --- cmds-check.c | 2 ++ 1 file changed, 2 insertions(+) diff --git a/cmds-check.c b/cmds-check.c index cf5a08ce..7d273623 100644 --- a/cmds-check.c +++ b/cmds-check.c @@ -5001,6 +5001,8 @@ static int check_fs_first_inode(struct btrfs_root *root, unsigned int ext_ref) if (ret > 0) { ret = 0; err |= INODE_ITEM_MISSING; + error("first inode item of root %llu is missing", + root->objectid); } err |= check_inode_item(root, &path, ext_ref); -- 2.11.0 -- To unsubscribe from this list: send the line "unsubscribe linux-btrfs" in the body of a message to majord...@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html