If first inode item is missing, lowmem check will detect it but not
output any error message.

Add error message for it.

Signed-off-by: Qu Wenruo <quwen...@cn.fujitsu.com>
---
 cmds-check.c | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/cmds-check.c b/cmds-check.c
index cf5a08ce..7d273623 100644
--- a/cmds-check.c
+++ b/cmds-check.c
@@ -5001,6 +5001,8 @@ static int check_fs_first_inode(struct btrfs_root *root, 
unsigned int ext_ref)
        if (ret > 0) {
                ret = 0;
                err |= INODE_ITEM_MISSING;
+               error("first inode item of root %llu is missing",
+                     root->objectid);
        }
 
        err |= check_inode_item(root, &path, ext_ref);
-- 
2.11.0



--
To unsubscribe from this list: send the line "unsubscribe linux-btrfs" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html