On 5.09.19 г. 10:57 ч., Qu Wenruo wrote:
> Before this patch, repair_imode_common() can only handle two types of
> inodes:
> - Free space cache inodes
> - ROOT DIR inodes
> 
> For inodes in subvolume trees, the core complexity is how to determine the
> correct imode, thus it was not implemented.
> 
> However there are more reports of incorrect imode in subvolume trees, we
> need to support such fix.
> 
> So this patch adds a new function, detect_imode(), to detect imode for
> inodes in subvolume trees.
> 
> That function will determine imode by:
> - Search for INODE_REF
>   If we have INODE_REF, we will then try to find DIR_ITEM/DIR_INDEX.
>   As long as one valid DIR_ITEM or DIR_INDEX can be found, we convert
>   the BTRFS_FT_* to imode, then call it a day.
>   This should be the most accurate way.
> 
> - Search for DIR_INDEX/DIR_ITEM
>   If above search fails, we falls back to locate the DIR_INDEX/DIR_ITEM
>   just after the INODE_ITEM.
>   If any can be found, it's definitely a directory.

This needs an explicit satement that it will only work for non-empty files and 
directories
> 
> - Search for EXTENT_DATA
>   If EXTENT_DATA can be found, it's either REG or LNK.
>   For this case, we default to REG, as user can inspect the file to
>   determine if it's a file or just a path.
> 
> - Use rdev to detect BLK/CHR
>   If all above fails, but INODE_ITEM has non-zero rdev, then it's either
>   a BLK or CHR file. Then we default to BLK.
> 
> - Fail out if none of above methods succeeded
>   No educated guess to make things worse.
> 
> Signed-off-by: Qu Wenruo <w...@suse.com>
> ---
>  check/mode-common.c | 130 +++++++++++++++++++++++++++++++++++++++-----
>  1 file changed, 117 insertions(+), 13 deletions(-)
> 
> diff --git a/check/mode-common.c b/check/mode-common.c
> index c0ddc50a1dd0..abea2ceda4c4 100644
> --- a/check/mode-common.c
> +++ b/check/mode-common.c
> @@ -935,6 +935,113 @@ out:
>       return ret;
>  }
>  
> +static int detect_imode(struct btrfs_root *root, struct btrfs_path *path,
> +                     u32 *imode_ret)
> +{
> +     struct btrfs_key key;
> +     struct btrfs_inode_item iitem;
> +     const u32 priv = 0700;
> +     bool found = false;
> +     u64 ino;
> +     u32 imode;
> +     int ret = 0;
> +
> +     btrfs_item_key_to_cpu(path->nodes[0], &key, path->slots[0]);
> +     ino = key.objectid;
> +     read_extent_buffer(path->nodes[0], &iitem,
> +                     btrfs_item_ptr_offset(path->nodes[0], path->slots[0]),
> +                     sizeof(iitem));
> +     /* root inode */
> +     if (ino == BTRFS_FIRST_FREE_OBJECTID) {
> +             imode = S_IFDIR;
> +             found = true;
> +             goto out;
> +     }
> +
> +     while (1) {
> +             struct btrfs_inode_ref *iref;
> +             struct extent_buffer *leaf;
> +             unsigned long cur;
> +             unsigned long end;
> +             char namebuf[BTRFS_NAME_LEN] = {0};
> +             u64 index;
> +             u32 namelen;
> +             int slot;
> +
> +             ret = btrfs_next_item(root, path);
> +             if (ret > 0) {
> +                     /* falls back to rdev check */
> +                     ret = 0;
> +                     goto out;
> +             }

In my testing if an inode is the last one in the leaf and it doesn't have 
an INODE_REF item then it won't be repaired. But e.g. it can have perfectly 
valid DIR_ITEM/DIR_INDEX entries which describe this inode as being a file. 
E.g. 

        item 2 key (256 DIR_ITEM 388586943) itemoff 16076 itemsize 35
                location key (260 INODE_ITEM 0) type FILE
                transid 7 data_len 0 name_len 5
                name: file3

        .....
        item 15 key (260 INODE_ITEM 0) itemoff 15184 itemsize 160
                generation 7 transid 7 size 0 nbytes 0
                block group 0 mode 26772225102 links 1 uid 0 gid 0 rdev 0
                sequence 1 flags 0x0(none)
                atime 1568127261.284993602 (2019-09-10 14:54:21)
                ctime 1568127261.284993602 (2019-09-10 14:54:21)
                mtime 1568127261.284993602 (2019-09-10 14:54:21)
                otime 1568127261.284993602 (2019-09-10 14:54:21)

I have intentionally deleted INODE_REF too see what's happening. Is this 
intended?


> +             if (ret < 0)
> +                     goto out;
> +             leaf = path->nodes[0];
> +             slot = path->slots[0];
> +             btrfs_item_key_to_cpu(leaf, &key, slot);
> +             if (key.objectid != ino)
> +                     goto out;
> +
> +             /*
> +              * We ignore some types to make life easier:
> +              * - XATTR
> +              *   Both REG and DIR can have xattr, so not useful
> +              */
> +             switch (key.type) {
> +             case BTRFS_INODE_REF_KEY:
> +                     /* The most accurate way to determine filetype */
> +                     cur = btrfs_item_ptr_offset(leaf, slot);
> +                     end = cur + btrfs_item_size_nr(leaf, slot);
> +                     while (cur < end) {
> +                             iref = (struct btrfs_inode_ref *)cur;
> +                             namelen = min_t(u32, end - cur - sizeof(&iref),
> +                                     btrfs_inode_ref_name_len(leaf, iref));
> +                             index = btrfs_inode_ref_index(leaf, iref);
> +                             read_extent_buffer(leaf, namebuf,
> +                                     (unsigned long)(iref + 1), namelen);
> +                             ret = find_file_type(root, ino, key.offset,
> +                                             index, namebuf, namelen,
> +                                             &imode);
> +                             if (ret == 0) {
> +                                     found = true;
> +                                     goto out;
> +                             }
> +                             cur += sizeof(*iref) + namelen;
> +                     }
> +                     break;
> +             case BTRFS_DIR_ITEM_KEY:
> +             case BTRFS_DIR_INDEX_KEY:
> +                     imode = S_IFDIR;

You should set found here. Otherwise this function returns ENOENT in those 2 
branches. 
BTW in relation to out private conversation I found this while trying to create 
test 
cases which will trigger all branches. The fact it found bugs proves we should 
strive 
for as much testing coverage as possible. 

> +                     goto out;
> +             case BTRFS_EXTENT_DATA_KEY:
> +                     /*
> +                      * Both REG and LINK could have EXTENT_DATA.
> +                      * We just fall back to REG as user can inspect the
> +                      * content.
> +                      */
> +                     imode = S_IFREG;
ditto

> +                     goto out;
> +             }
> +     }
> +
> +out:
> +     /*
> +      * Both CHR and BLK uses rdev, no way to distinguish them, so fall back
> +      * to BLK. But either way it doesn't really matter, as CHR/BLK on btrfs
> +      * should be pretty rare, and no real data will be lost.
> +      */
> +     if (!found && btrfs_stack_inode_rdev(&iitem) != 0) {
> +             imode = S_IFBLK;
> +             found = true;
> +     }
> +
> +     if (found)
> +             *imode_ret = (imode | priv);
> +     else
> +             ret = -ENOENT;
> +     return ret;
> +}
> +
>  /*
>   * Reset the inode mode of the inode specified by @path.

<snip>

Reply via email to