When refer file "directly" (e.g. ls -li <filename>),
 if file is same name, old inode cache is used.
This causes that client shows wrong(old) inode number.
So this patch is that if uniqueid is different, return error.

## But this patch is applicable to when Server is UNIX.
## When Server is Windows, we need another new patch.


Reproducible sample :
1. create file 'a' at cifs client.
2. rm 'a' and touch 'b a' at server.
3. ls -li 'a' at client, then client shows wrong(old) inode number.

Bug link:
https://bugzilla.kernel.org/show_bug.cgi?id=90021



Signed-off-by: Nakajima Akira <[email protected]>
diff -uprN -X linux-3.18-vanilla/Documentation/dontdiff 
linux-3.18-vanilla/fs/cifs/inode.c linux-3.18/fs/cifs/inode.c
--- linux-3.18-vanilla/fs/cifs/inode.c  2014-12-08 07:21:05.000000000 +0900
+++ linux-3.18/fs/cifs/inode.c  2014-12-19 11:07:59.127000000 +0900
@@ -402,9 +402,18 @@ int cifs_get_inode_info_unix(struct inod
                        rc = -ENOMEM;
        } else {
                /* we already have inode, update it */
+
+               /* if uniqueid is different, return error */
+               if (unlikely(cifs_sb->mnt_cifs_flags & CIFS_MOUNT_SERVER_INUM &&
+                   CIFS_I(*pinode)->uniqueid != fattr.cf_uniqueid)) {
+                       rc = -ENOENT;
+                       goto cgiiu_exit;
+               }
+
                cifs_fattr_to_inode(*pinode, &fattr);
        }
 
+cgiiu_exit:
        return rc;
 }
 
--
To unsubscribe from this list: send the line "unsubscribe linux-cifs" in
the body of a message to [email protected]
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to