On Wed, Aug 22, 2007 at 04:49:04PM +0200, Borgström Jonas wrote:
> Yes, both "fence_drac ..." and "fence_node test-db1.example.com" works.
> 
> The strange thing is that during the test I described earlier it looks like 
> the cluster didn't even try to fence the failed node. /var/log/messages 
> didn't mentioning anything about trying to fence any node. And neither did 
> "group_tool dump fence".
> 
> And even if something would be wrong with the fence_drac configuration 
> wouldn't fence_manual kick in instead?

Yes.  Also, it looks like fencing did not "quietly" complete - since
rgmanager never recovered (failed-over) the service from the dead node.

If a node dies unexpectedly, rgmanager waits until cman has finished
fencing that node before initiating a failover.  That's why it was
still reported as 'started' on the dead node in the clustat output.

-- Lon

-- 
Lon Hohberger - Software Engineer - Red Hat, Inc.

--
Linux-cluster mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/linux-cluster