Hi!

Process I followed similar to what we test for Veritas Clusters.

For two node cluster:

Perform these test on both nodes.

1. Pull out the Ethernet cable, If the  channel bonding is implemented then 
both.
2. Reboot the server.
3. Power Cycle (forcibly)
4. Disconnect the Fiber cable to simulate fabric failures.
5. Kill the CMAN/rgmanager/qdiskd
6. Manually fence the other node.

Check messages files for any other errors.

Any one has more suggestion ?

Thanks,

Nitin

-----Original Message-----
From: [email protected] 
[mailto:[email protected]] On Behalf Of Steve OBrien
Sent: Wednesday, September 30, 2009 4:32 PM
To: [email protected]
Subject: [Linux-cluster] Cluster Pre-Production testing

Does anyone have a reliable method for testing a cluster before putting
it into production?

TIA,
Steve


--
Linux-cluster mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/linux-cluster

--
Linux-cluster mailing list
[email protected]
https://www.redhat.com/mailman/listinfo/linux-cluster

Reply via email to