Thanks to all !!!! [email protected]
On Thu, Mar 4, 2010 at 12:00 AM, Lon Hohberger <[email protected]> wrote: > On Wed, 2010-03-03 at 13:10 +0200, שלום קלמר wrote: > > Hi. > > > > I got 2 power supplies. But if someone by mistake pull the power > > cables , is that mean > > > > That the services will not failover ?? > > The problem is: > > no power = no ping + no DRAC access > no network = no ping, no DRAC access > > If there's no power, then it is safe to fail over. > > If there is no network (and power is OK), then it is not safe to fail > over. Failover in this case is very likely to produce data corruption! > > Because we can not tell which case happened, we do not fail over. > > -- Lon > > > -- > Linux-cluster mailing list > [email protected] > https://www.redhat.com/mailman/listinfo/linux-cluster >
-- Linux-cluster mailing list [email protected] https://www.redhat.com/mailman/listinfo/linux-cluster