Well, after reading man openais.conf the settings below seemed ok for this operation, so I just went ahead with it. I connected the old and new switch and moved the cluster nodes over one by one (which meant the link was down for 4-5 seconds). There were no problems whatsoever.
Cheers, Martijn On Fri, Jun 17, 2011 at 9:26 AM, Martijn Storck <[email protected]>wrote: > Hi all, > > Unfortunately I have to swap out the switch that is used for the cluster > traffic of our 4-node cluster for a new one. I'm hoping I can do this by > connecting the new switch to the old switch and then moving the nodes over > one by one. > > Can I change the cluster configuration so that there is a longer grace > period before a node is deemed 'lost' and gets fenced? The only line in my > cluster.conf that looks like it has anything to do with it is this one: > > <totem consensus="4800" join="60" token="10000" > token_retransmits_before_loss_const="20"/> > > I think that with faststart enabled the link with a node will be down for > only a few seconds. I realize that this probably means the cluster will lock > up during that period (since we use a lot of GFS), but it's still better > than having to bring the entire cluster down. > > Kind regards, > Martijn Storck >
-- Linux-cluster mailing list [email protected] https://www.redhat.com/mailman/listinfo/linux-cluster