Hello,

I did some tests on 4 nodes cluster with quorum device and I find a bad 
situation with one test, so I need your knowledges to correct my configuration.

Configuation:
4 nodes, all vote for 1
quorum device vote for 1 (to hold services with minimum 2 nodes up)
cman expected votes 5

Situation:
I shut down network on 2 nodes, one of them is master.

Observation:
Fencing of one node (the master)... Quorum device Offline, Quorum disolved ! 
Services stopped.
Fenced node reboot, cluster is quorate, 2nd offline node is fenced. Services 
restart.
2nd node offline reboot.

My cluster is not quorate for 8 min (very long hardware boot :-) and my 
services were offline.

Do you know how to prevent this situation?

Regards,

-- 
  .`'`.   GouNiNi
 :  ': :  
 `. ` .`  GNU/Linux
   `'`    http://www.geekarea.fr

--
Linux-cluster mailing list
Linux-cluster@redhat.com
https://www.redhat.com/mailman/listinfo/linux-cluster

Reply via email to