Hello, I have a RHEL 6.5 cluster, using rgmanager. The fence devices are fence_ipmilan - fencing through HP iLO4.
The issue is the fence devices weren't configured entirely correct - recently after a node failure, the fence agent was returning failures (even though it was fencing the node successfully), which apparently can be avoided by setting the power_wait option to the fence dev configuration. My question is - after changing the fence device (I think directly through the .conf will be fine?), iterating the config version, and syncing the .conf through the cluster software - is something else necessary to apply the change (eg. cman reload)? Will the new fence option be used the next time a fencing action is performed? And lastly can all of this be performed while the cluster and services are operational or they have to be stopped/restarted? Regards, Vasil
-- Linux-cluster mailing list Linux-cluster@redhat.com https://www.redhat.com/mailman/listinfo/linux-cluster