Now this is wierd.  Are you sure this is the case in RH60?  Because ttyS1 is
definitely COM1 for the systems that I have set up (otherwise I would see no
output thru COM1, correct?).

S. --��--- mailto:[EMAIL PROTECTED]

----- Original Message -----
From: Dave Mielke <[EMAIL PROTECTED]>
To: Simon Yeo <[EMAIL PROTECTED]>
Cc: Dave Mielke <[EMAIL PROTECTED]>; Christian Reis
<[EMAIL PROTECTED]>; linux admin <[EMAIL PROTECTED]>;
Linux Config Email List <[EMAIL PROTECTED]>
Sent: Friday, September 24, 1999 2:03 PM
Subject: Re: serial console problem


> On Fri, 24 Sep 1999, Simon Yeo wrote:
> >Here's what I have in my lilo.conf:
> >
> >serial=1,19200n8
> >append="console=ttyS1,19200"
> >
> >This works thru my com1 port.
>
> No, you have specified your COM2 port. In DOS the serial port numbers
start
> from 1, whereas in Linux they start from 0. COM1<->ttyS0
>
> --
> Dave Mielke           | 856 Grenon Avenue | I believe that the Bible is
the
> Phone: 1-613-726-0014 | Ottawa, Ontario   | Word of God. Please contact me
> EMail: [EMAIL PROTECTED] | Canada  K2B 6G3   | if you're concerned about
Hell.
>

Reply via email to