On 7/4/25 10:53 AM, [email protected] wrote: > From: Chia-Yu Chang <[email protected]> > > In simultaneous connect scenario, the connection will be established > when SYN/ACK is received after patch 23e89e8ee7be7. However, the > third ACK is still anticipated to complete the negotiation for either > RFC3168 ECN and Accurate ECN. In this sense, an additional flag > wait_third_ack is introduced to identify that the 3rd ACK is still > anticipated to ensure ECN or AccECN negotiation will be done in the > ESTABLISHED state. > > Signed-off-by: Chia-Yu Chang <[email protected]> > Co-developed-by: Ilpo Järvinen <[email protected]> > Signed-off-by: Ilpo Järvinen <[email protected]>
I saw there are existing pktdrill test for ECN with simultaneous connect, but I'm still wondering it there is a real use case behind? AFAICS simult connect can happen only on loopback, and [Acc]ECN on loopback looks useless. I would simply not allow AccECN on simultaneous connect - assuming that would basically drop all the code in this patch without no fourther modification required. /P