Hi Marko,

Marko KenttXlX wrote:
Hullo,

More results of my VES1820 register hacking:

What is the purpose of PWMREF (0x34) register? It is obviously pulse width modulated configuration register but for what? Default value for it in my Siemens DVB-C rev. 1.5 is 0x52 but if I use for example 0x46 I get my BER halfed and less block errors.

Datasheet says:

The value that will be PWM encoded and output on pin FEL when parameter FELPWM of register AGCCONF (index 02) is set to 1.
the datasheet I have here says:

"By default FEL is a front-end lock indicator. [...] But FEL can also be configured to output a PWM signal, which value can be programmed through the i2c interface (see register PWMREF, index 0x34)."

Unfortunally I don't know what's connected to this pin on the Siemens cards, so I can't help you much more...

Maybe you want to trace the wire? At the end we probably should pragmatically program the values that work best.

Holger



--
Info:
To unsubscribe send a mail to [EMAIL PROTECTED] with "unsubscribe linux-dvb" as subject.



Reply via email to