On Mon, Jun 21, 2004 at 06:03:16PM +0200, M�ns Rullg�rd wrote:
> Johannes Stezenbach <[EMAIL PROTECTED]> writes:
> 
> > The PCR values are there where they should be, on PID 0x8ad.
> > What makes you think they are not?
> 
> The simple fact that none of the TS packets have the PCR flag set in
> the adaptation field.  Is there another method of encoding the PCR
> that I am not aware of?  A small sample of what I am receiving is at
> http://mru.ath.cx/~mru/samples/euronews.ts.  If anyone can find a PCR
> value in that sample I'd be thankful to know how it was done.

Currently on Euronews I see something like:

4708ad2bb7104b2072f4fe27ffffffffffffffffffffffffffffffffffffffffffff

But in your sample there are indeed no PCRs. You know that the
AV7110 corrupts adaptation fields for the streams it is
currently decoding, do you?

Johannes


Reply via email to