On 2024/9/5 14:00, Sandeep Dhavale wrote:
If we get a failure at the first decompressor init (i = 0), the clean up while loop could enter infinite loop due to wrong while check. Check the value of i now to see if we need any clean up at all.Fixes: 5a7cce827ee9 ("erofs: refine z_erofs_{init,exit}_subsystem()") Reported-by: liujinbao1 <[email protected]> Signed-off-by: Sandeep Dhavale <[email protected]>
Reviewed-by: Chao Yu <[email protected]> Thanks,