Marcelo Tosatti wrote:
Hi Alan, list members,

The attached patch (heartbeat-mult-outlet-V4.patch) updates the cyclades
STONITH module as follows:

Changelog:
* Support new PM firmware format
* Support multiple outlets connected to a single host by truncating the
comparison to the hostname length defined in the heartbeat configuration.
* Increase maximum outlet name length to 16 characters.
* Add README.cyclades file which for some reason was not incorporated
to the official heartbeat package.

Hi Marcelo,

The main question I have is this:

Does this new version work with the old versions of firmware?

If not, then we need a version that's adaptive, and works with both old and new versions of firmware.

--
    Alan Robertson <[EMAIL PROTECTED]>

"Openness is the foundation and preservative of friendship... Let me claim from you at all times your undisguised opinions." - William Wilberforce
_______________________________________________________
Linux-HA-Dev: [email protected]