On 4/19/07, Peter Kruse <[EMAIL PROTECTED]> wrote:
Hi Andrew!
Andrew Beekhof wrote:
> beosrv-c-2 is the failed node right?
it was beosrv-c-1 that failed, beosrv-c-2 took over.
then i'm afraid your use of the "dont fence nodes on startup" option
has come back to haunt you
beosrv-c-1 came up but was not able to find beosrv-c-2 (even though it
_was_ running) and because of that option beosrv-c-1 just pretended
beosrv-c-2 wasn't running and happily started activating resources.
remember how we said that option wasn't a good idea :-)
>
> do you have logs from there too?
attached (messages about Gmain_timeout removed, there were too many
of them)
The problem now is that cibadmin -m reports:
CIB on localhost _is_ the master instance
on both nodes.
Thanks for your time,
Peter