On 8/10/07, Rob Aronson <[EMAIL PROTECTED]> wrote: > I have SLES 10 with the following versions fo heartbeat > heartbeat-stonith-2.0.7-1.2 > heartbeat-cmpi-2.0.7-1.2 > yast2-heartbeat-2.13.10-1.3 > heartbeat-2.0.7-1.2 > heartbeat-ldirectord-2.0.7-1.2 > heartbeat-pils-2.0.7-1.2
do please upgrade to SP1 (SUSE support will send you packing until you do) > The line you couldn't parse correctly was meant to convey: > I was trying to emulate loss of network connectivity in a cluster node by > shutting down the primary network interface. to the outside world or to the other machine? > In my two node cluster with > resource groups assigned to each node I had thought the correct behavior of > the cluster would be upon loss of connectivity in a node, the cluster would > remove the resources from the node with out connectivity and then the > stonith daemon would take over and restart the disconnected node to make > sure it couldn't have a split brain condition. This is what happened when I > did the test the first time. The second time my 2 stonith resources were > stopped and the node without network access was left running. In a yet-to-be-released version, we ensure that all stonith-related operations are complete before stopping stonith resources. This is probably what you're seeing. > This is a sample of the log files off of both cluster nodes please make sure logs are sent as file attachments - most mail clients mangle them beyond recognition _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems
