On Fri, Feb 22, 2008 at 4:17 PM, Ryan Thomson <[EMAIL PROTECTED]> wrote: > Here are some instructions for SLES9, since they mention the lack of > rpc.statd, I think this should probably point you in the right direction. > > http://www.gatsby.ucl.ac.uk/~johnp/compute/ha-nfs-sles9.html > > Pay careful attention to the part about /sbin/sm-notify.
Thanks for the link to this article. I had completely overlooked sm-notify and found one other problem thanks to this link. My Major/Minors were off by one on both nodes. Once I corrected both issues, I had my first successful failover. Thanks!! _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems