Hi, On Wed, Jun 04, 2008 at 10:38:16AM +0200, Zoltan Boszormenyi wrote: > > We had a similar problem at a customer. The solution was to set these: > > ilo_can_reset = 1 > ilo_powerdown_method = reset > > Despite the reset method, the machine was powered down.
Instead of being rebooted? Did you try a riloe management client (I suppose that there is one)? > We also tried > > ilo_powerdown_method = button > > but this made the stonith resource to fail to start when one nodes was > powering up while the other stayed powered down. Sorry, don't get this one. A stonith resource would fail to start in case the monitor operation fails, e.g. when the stonith device is not reachable. I don't see how that should be the case, unless the whole box looses power. Disclaimer: No experience with riloe. Thanks, Dejan _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems