On Thu, Dec 17, 2009 at 10:54 AM, Tobias Appel <[email protected]> wrote:
> On 12/16/2009 05:42 PM, Artur Kamiński wrote:
>> Andrew Beekhof pisze:
>>> On Wed, Dec 16, 2009 at 8:48 AM, artur.k<[email protected]>  wrote:
>>>
>>>> I have built a cluster with two nodes on pacemacker 1.0.4 + DRBD (8.0.14). 
>>>> If one machine is restarted after returning pacemacker trying to switch 
>>>> all services to this server. How to prevent it?
>>>>
>>>
>>> Set default-resource-stickiness to something higher than 200.
>>> If you don't want it to move under any circumstances, set it to INFINITY.
>>>
>
> Will there still be a failover if it is set to INFINITY and one resource
> can't run on the current node (fails, is restarted but fails again and
> so on)?

Yes. INFINITY + -INFINITY = -INFINITY
Any node with a negative score for a resource cannot host that resource.