Hi...
I am configuring a cluster SLES 11 - SP1. But when defining the resource
stonith (RILO - HP Proliant), this error occurring...
After forcing the failure of a node (network failure), the node is restarted
and resources are migrated to another node.
But (strange behavior), after some minutes the second node that is full
featured (integro status), is also restarted.
Can someone help me ...
Follows the example:
<primitive class="stonith" id="ST_ILO_LEGADOPRD1" type="external/riloe">
<operations id="ST_ILO_LEGADOPRD1-operations">
</operations>
<instance_attributes id="ST_ILO_LEGADOPRD1-instance_attributes">
<nvpair id="ST_ILO_LEGADOPRD1-instance_attributes-hostlist"
name="hostlist" value="legadoprd1"/>
<nvpair id="ST_ILO_LEGADOPRD1-instance_attributes-ilo_hostname"
name="ilo_hostname" value="192.168.2.103"/>
<nvpair id="ST_ILO_LEGADOPRD1-instance_attributes-ilo_user"
name="ilo_user" value="Administrator"/>
<nvpair id="ST_ILO_LEGADOPRD1-instance_attributes-ilo_password"
name="ilo_password" value="V9P25HGC"/>
<nvpair
id="ST_ILO_LEGADOPRD1-instance_attributes-ilo_powerdown_method"
name="ilo_powerdown_method" value="power"/>
</instance_attributes>
<meta_attributes id="ST_ILO_LEGADOPRD1-meta_attributes">
<nvpair id="ST_ILO_LEGADOPRD1-meta_attributes-target-role"
name="target-role" value="started"/>
</meta_attributes>
</primitive>
<primitive class="stonith" id="ST_ILO_LEGADOPRD2" type="external/riloe">
<operations id="ST_ILO_LEGADOPRD2-operations">
</operations>
<instance_attributes id="ST_ILO_LEGADOPRD2-instance_attributes">
<nvpair id="ST_ILO_LEGADOPRD2-instance_attributes-hostlist"
name="hostlist" value="legadoprd2"/>
<nvpair id="ST_ILO_LEGADOPRD2-instance_attributes-ilo_hostname"
name="ilo_hostname" value="192.168.2.111"/>
<nvpair id="ST_ILO_LEGADOPRD2-instance_attributes-ilo_user"
name="ilo_user" value="Administrator"/>
<nvpair id="ST_ILO_LEGADOPRD2-instance_attributes-ilo_password"
name="ilo_password" value="N7KXR2CJ"/>
<nvpair
id="ST_ILO_LEGADOPRD2-instance_attributes-ilo_powerdown_method"
name="ilo_powerdown_method" value="power"/>
</instance_attributes>
<meta_attributes id="ST_ILO_LEGADOPRD2-meta_attributes">
<nvpair id="ST_ILO_LEGADOPRD2-meta_attributes-target-role"
name="target-role" value="stopped"/>
</meta_attributes>
</primitive>
Att, Marcio Hugo
Technology Consultant, EB HPS Technology Services
Hewlett-Packard Company
+55 11 7148 2184 / Mobile
[email protected] / Email
Av. Tamboré, 74/200
Barueri, SP 06400-000 - Brazil
_______________________________________________
Linux-HA mailing list
[email protected]
http://lists.linux-ha.org/mailman/listinfo/linux-ha
See also: http://linux-ha.org/ReportingProblems