Hi, Just wanted to ask how to contribute some info to the project. I built a Novell/NetIQ IDM Cluster using the eDir88 OCF script and found an issue with IDM Monitoring. I have not verified any of my suppositions with Novell, but it appears there are some constraints around the IDM Monitoring feature in the script.
The eDir88 scripts use the presence/absence of the vrdim module to detect when IDM is or is not loaded. One thing I found was that it does not appear to be enough that you have installed IDM and built a driver set, but you must have a working driver as well. I installed IDM and created a driver set, then turned on IDM monitoring and the eDirectory resource kept failing. It appears that vrdim does not load until there exists a driver in the driver set. Since the eDirectory resource kept crashing, I was not able to create one until I discovered that and turned off IDM Monitoring. Once I built a driver, I could see that vrdim was being loaded whenever eDirectory was started. Turning on the IDM monitoring at this point was successful and the eDirectory resource then worked as planned. -- Tim Edmonds PTCats LLC [email protected] 636 578-1342 _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems