Le 12/11/2012 13:27, [email protected] a écrit : > Hi Andrew, > > I'm using pacemaker-1.1.7-6 > > On my resources I set on-fail=fence on the op monitor, and to test it, I > just > stop manually the resource out of Pacemaker to lead to a monitoring failed > in Pacemaker, > but with this release the resource is restarted on same node , and the > other node does > not even try to fence the local node ... > > Besides, it was working fine in older releases, meaning the node was well > fenced in this test case. > > Is it a known bug or regression ? Is there a patch file somewhere ?
I'm not Andrew but I believe that before declaring the resource as failed, on an unsuccessful op.monitor() the cluster first tries to restart the resource, which in your case, will succeed. But I cannot find anything in the documentation to prove that, sadly. You'd rather use: crm resource failcount foo set X (or return a wrong exit code from the init-script, or make sure that the service cannot start anymore) -- Cheers, Florian Crouzat _______________________________________________ Linux-HA mailing list [email protected] http://lists.linux-ha.org/mailman/listinfo/linux-ha See also: http://linux-ha.org/ReportingProblems