On 15/05/17 02:54, Guenter Roeck wrote:
> On 05/10/2017 08:45 PM, Chris Packham wrote:
>> By default adt7475 will stop the fans (pwm duty cycle 0%) when the
>> temperature drops past Tmin - hysteresis. Some systems want to keep the
>> fans moving even when the temperature drops so add new sysfs attributes
>> that configure the enhanced acoustics min 1-3 which allows the fans to
>> run at the minimum configure pwm duty cycle.
>>
>> Signed-off-by: Chris Packham <chris.pack...@alliedtelesis.co.nz>
>> ---
>>
>> Changes in v2:
>> - use pwmN_stall_dis as the attribute name. I think this describes the 
>> purpose
>>   pretty well. I went with a new attribute instead of overloading
>
> Almost agree. Can we use pwmN_stall_disable ?
>

Sold. I'll send a v4 of this patch with the name changed.

> Thanks,
> Guenter
>
>
>>   pwmN_auto_point1_pwm so this doesn't affect existing users.
>> Changes in v3:
>> - Fix grammar.
>> - change enh_acou to enh_acoustics

--
To unsubscribe from this list: send the line "unsubscribe linux-hwmon" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to