From: Iker Perez del Palomar Sustatxa <[email protected]>

This patch series adds support for the TMP75 temperature sensor to the 
lm75.c driver. Although the TMP75B has a configurable conversion rate,
this series just sets it to the default rate of 37Hz. Sample rate is set 
close to this.           
                                                                                
 
In the future, I want to develop a function that allows the user choose        
the preferred conversion rate from user-land. 


Iker Perez del Palomar Sustatxa (2):
  hwmon: (lm75) Add support for TMP75B
  dt-bindings: hwmon: Add tmp75b to lm75.txt

 Documentation/devicetree/bindings/hwmon/lm75.txt |  1 +
 Documentation/hwmon/lm75                         |  7 +++++--
 drivers/hwmon/lm75.c                             | 11 +++++++++++
 3 files changed, 17 insertions(+), 2 deletions(-)

-- 
2.11.0