On Wed, Sep 11, 2019 at 05:28:14PM -0700, Nicolin Chen wrote:
> Hello Guenter,
> 
> Datasheet: http://www.ti.com/lit/ds/symlink/ina3221.pdf
> (At page 32, chapter 8.6.2.14 and 8.6.2.15)
> 
> I have two registers that I need to expose to user space:
>       Shunt-Voltage-Sum and Shunt-Voltage-Limit registers
> 
> Right now in[123]_input of INA3221 are for voltage channels
> while in[456]_input are for Shunt voltage channels.
> 
> So can I just use in7_input and in7_crit for them?
> 
Doesn't Shunt-Voltage-Limit apply to in[456]_input ?
If so, the limit should be attached to those.
in7_input for Shunt-Voltage-Sum would be fine.

Guenter