> -----Original Message----- > From: Ed Swierk [mailto:[email protected]] > Sent: Tuesday, January 06, 2009 11:14 PM > To: BARRE Sebastien > Cc: [email protected]; David Brownell; Alessandro Zummo; linux- > [email protected]; Andrew Morton > Subject: Re: [PATCH] rtc-ds1307: True SMBus compatibility > > On Tue, Jan 6, 2009 at 5:35 AM, BARRE Sebastien <[email protected]> wrote: > > I've read your patch quicly, I will test it on my board as soon as > possible. > > Thanks. > > > You can delete the next 3 lines, they are not useful: > > > >> + ret = ds1307_read_block_data_once(client, command, length, > currvalues); > >> + if (ret < 0) > >> + return ret; > > Oops! Here is an updated patch with these lines removed, and a minor > formatting fix. > > Signed-off-by: Ed Swierk <[email protected]> > > --Ed
I've tested the patch on my geode LX board with a DS1307 device. It works well for me. However I think writing the clock one byte at a time could cause strange behavior when using alarms on device like ds1337. Tested-by: Sébastien Barré <[email protected]> -- Sébastien Barré Bureau d'étude - Développement SDEL Contrôle Commande D2A - Rue Nungesser et Coli 44860 Saint Aignan de Grand Lieu FRANCE Tél : +33(0)2 40 84 50 88 Fax : +33(0)2 40 84 51 10 N�����r��y����b�X��ǧv�^�){.n�+����{��g"��^n�r���z���h�����&���G���h�(�階�ݢj"���m������z�ޖ���f���h���~�m�