On Sun, Oct 06, 2013 at 02:02:13PM +0200, Marek Vasut wrote:
> Analyze and rework the PIO mode operation. The PIO mode operation
> was unreliable on MX28, by analyzing the bus with LA, the checks
> for when data were available or were to be sent were wrong.
> 
> The PIO WRITE has to be completely reworked as it multiple problems.
> The MX23 datasheet helped here, see comments in the code for details.
> The problems boil down to:
> - RUN bit in CTRL0 must be set after DATA register was written
> - The PIO transfer must be 4 bytes long tops, otherwise use
>   clock stretching.
> Both of these fixes are implemented.
> 
> The PIO READ operation can only be done for up to four bytes as
> we are unable to read out the data from the DATA register fast
> enough.
> 
> This patch also tries to document the investigation within the
> code.
> 
> Signed-off-by: Marek Vasut <[email protected]>

Applied the series to for-next, thanks!

>     (and fixed my local pre-commit hook)

Yay :)