> It's for draining.  Let's say drive says it wanna transfer 18 bytes but
> the buffer is only 13 bytes long.  If the transfer method consumes 2
> bytes per read, it would consume 14 bytes.  If the transfer method
> consumes 4 bytes per read, it would consume 16 bytes.  If we drain too
> much, we risk hanging the machine.

Do we have any actual cases where trying to drain beyond the controller
granuality is a problem ?

Might be cleaner to sort this (and the DMA assumption of 2 byte
alignment, and possibly 16 byte for some devices/controllers) with 

        dev->pio_io_size;
        dev->dma_io_size;

-
To unsubscribe from this list: send the line "unsubscribe linux-ide" in
the body of a message to [EMAIL PROTECTED]
More majordomo info at  http://vger.kernel.org/majordomo-info.html