you need to connect two rj45 connectors on each side of the cable.Hi, I have a 4-pair CAT-5 cable between two floors in my house. I was wondering if I can use this 4-pair cable instead of two CAT-5 cables to connect to a switch I have at one location.
The toplogy is:
PC3_ PC1\ __ \ >====4-pair=cable===< |^^^^^^^^| PC2/ \_| SWITCH | PC4___|________|
Can this work?
Alon
one pair to pins 1,2 of connectors A and B (A from one side of the line, B on the other)
one pair to pins 3,6 of connectors A and B
one pair to pins 1,2 of connectors C and D
one pair to pins 3,6 of connectors C and D
it should work if the cable is not too long
cheers, erez.