Alon Altman wrote:

Hi,
 I have a 4-pair CAT-5 cable between two floors in my house. I was
wondering if I can use this 4-pair cable instead of two CAT-5 cables to
connect to a switch I have at one location.

The toplogy is:

                       PC3_
PC1\                     __ \
   >====4-pair=cable===<  |^^^^^^^^|
PC2/                     \_| SWITCH |
                    PC4___|________|

Can this work?

Alon



you need to connect two rj45 connectors on each side of the cable.

one pair to pins 1,2 of connectors A and B (A from one side of the line, B on the other)
one pair to pins 3,6 of connectors A and B
one pair to pins 1,2 of connectors C and D
one pair to pins 3,6 of connectors C and D


it should work if the cable is not too long

cheers,
erez.



=================================================================
To unsubscribe, send mail to [EMAIL PROTECTED] with
the word "unsubscribe" in the message body, e.g., run the command
echo unsubscribe | mail [EMAIL PROTECTED]



Reply via email to