On Thu, 15 Oct 2015, Jason Gerecke wrote:

> The new Intuos tablets added in eda01da and the Cintiq 13HD Touch added
> in b4bf212 are capable of reporting 2048 levels of pressure. Although the
> kernel reports the correct range to userspace, an oversight has resulted
> in the driver ingoring the 11th pressure bit and only sending pressures
> of 0 through 1023.
> 
> We could fix this issue by expanding the type check to include these
> devices, but it makes much more sense to just have the driver look at
> the device's maximum pressure when determining if it should read the
> 11th bit.
> 
> Signed-off-by: Jason Gerecke <jason.gere...@wacom.com>

Applied to for-4.4/wacom.

-- 
Jiri Kosina
SUSE Labs

--
To unsubscribe from this list: send the line "unsubscribe linux-input" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to