On 08/23/2016 08:46 AM, Peter Zijlstra wrote: I have 2 more comments about the code.1) There are a couple of places where you only use 0x3 in mutex.c. They should be replaced by the symbolic name instead. 2) We should make __mutex_lock_slowpath() a noinline function just like __mutex_lock_killable_slowpath() or __mutex_lock_interruptible_slowpath().
Cheers, Longman