Hi, On Thu, Aug 25, 2016 at 03:19:52PM +0800, Wenyou Yang wrote: > When get the property, first check the charger state machine, > then check the status bit to decide what value is assigned to > the corresponding property. > > Retain the SUSCHG bit of REG 0x71 when configure the timers to > avoid losting the charger suspending info after boot. > > Signed-off-by: Wenyou Yang <[email protected]> > Signed-off-by: Fengguang Wu <[email protected]>
Thanks, queued. -- Sebastian
signature.asc