On Mon, 26 Sep 2016, Peter Zijlstra wrote:

> There is but a single user and the previous patch mandates slowfn must
> be rt_mutex_slowunlock(), so fold the lot together and save a few
> lines.

We might have to bring that back for RT, but ok :)

Reviewed-by: Thomas Gleixner <t...@linutronix.de>