On Wed, Oct 26, 2016 at 09:00:52PM +0200, ahas...@baylibre.com wrote: > From: Axel Haslam <ahas...@baylibre.com> > > Regulator consumers may be interested to know when the > over current condition is over. > > Add an over currerent "changed" event. The registered useres > for this event can then check the over current flag to know > the status of the over current condition.
Would a more general event for error conditions work as well? Thinking about this I'm unclear how interested consumers are going to be in the specific error condition as opposed to the fact that the regulator ran into trouble, and I can imagine that some regulators will report the same root cause differently - another regulator might detect an excessive current draw by seeing the output voltage collapse and the regulator go out of regulation for example.