3.16.39-rc1 review patch.  If anyone has any objections, please let me know.

------------------

From: "Kweh, Hock Leong" <[email protected]>

commit 36afb176d3c9580651d7f410ed7f000ec48b5137 upstream.

According to IIO ABI definition, IIO_PRESSURE data output unit is
kilopascal:
http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio

This patch fix output unit of HID pressure sensor IIO driver from pascal to
kilopascal to follow IIO ABI definition.

Signed-off-by: Kweh, Hock Leong <[email protected]>
Reviewed-by: Srinivas Pandruvada <[email protected]>
Signed-off-by: Jonathan Cameron <[email protected]>
Signed-off-by: Ben Hutchings <[email protected]>
---
 drivers/iio/common/hid-sensors/hid-sensor-attributes.c | 4 ++--
 1 file changed, 2 insertions(+), 2 deletions(-)

--- a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
+++ b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c
@@ -56,8 +56,8 @@ struct {
        {HID_USAGE_SENSOR_ALS, 0, 1, 0},
        {HID_USAGE_SENSOR_ALS, HID_USAGE_SENSOR_UNITS_LUX, 1, 0},
 
-       {HID_USAGE_SENSOR_PRESSURE, 0, 100000, 0},
-       {HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 1, 0},
+       {HID_USAGE_SENSOR_PRESSURE, 0, 100, 0},
+       {HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 0, 1000},
 };
 
 static int pow_10(unsigned power)

Reply via email to