3.16.39-rc1 review patch. If anyone has any objections, please let me know.
------------------ From: "Kweh, Hock Leong" <[email protected]> commit 36afb176d3c9580651d7f410ed7f000ec48b5137 upstream. According to IIO ABI definition, IIO_PRESSURE data output unit is kilopascal: http://lxr.free-electrons.com/source/Documentation/ABI/testing/sysfs-bus-iio This patch fix output unit of HID pressure sensor IIO driver from pascal to kilopascal to follow IIO ABI definition. Signed-off-by: Kweh, Hock Leong <[email protected]> Reviewed-by: Srinivas Pandruvada <[email protected]> Signed-off-by: Jonathan Cameron <[email protected]> Signed-off-by: Ben Hutchings <[email protected]> --- drivers/iio/common/hid-sensors/hid-sensor-attributes.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) --- a/drivers/iio/common/hid-sensors/hid-sensor-attributes.c +++ b/drivers/iio/common/hid-sensors/hid-sensor-attributes.c @@ -56,8 +56,8 @@ struct { {HID_USAGE_SENSOR_ALS, 0, 1, 0}, {HID_USAGE_SENSOR_ALS, HID_USAGE_SENSOR_UNITS_LUX, 1, 0}, - {HID_USAGE_SENSOR_PRESSURE, 0, 100000, 0}, - {HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 1, 0}, + {HID_USAGE_SENSOR_PRESSURE, 0, 100, 0}, + {HID_USAGE_SENSOR_PRESSURE, HID_USAGE_SENSOR_UNITS_PASCAL, 0, 1000}, }; static int pow_10(unsigned power)