From: Stefan Kristiansson <[email protected]>

During page fault handling we check the last instruction to understand
if the fault was for a read or for a write.  By default we fall back to
read.  New instructions were added to the openrisc 1.1 spec for an
atomic load/store pair (l.lwa/l.swa).

This patch adds the opcode for l.swa (0x33) allowing it to be treated as
a write operation.

Signed-off-by: Stefan Kristiansson <[email protected]>
[[email protected]: expanded a bit on the comment]

Signed-off-by: Stafford Horne <[email protected]>
---
 arch/openrisc/kernel/entry.S | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/openrisc/kernel/entry.S b/arch/openrisc/kernel/entry.S
index 572d223..aac0bde 100644
--- a/arch/openrisc/kernel/entry.S
+++ b/arch/openrisc/kernel/entry.S
@@ -264,7 +264,7 @@ EXCEPTION_ENTRY(_data_page_fault_handler)
        l.srli  r6,r6,26                   // check opcode for write access
 #endif
 
-       l.sfgeui r6,0x34                   // check opcode for write access
+       l.sfgeui r6,0x33                   // check opcode for write access
        l.bnf   1f
        l.sfleui r6,0x37
        l.bnf   1f
-- 
2.7.4