On Wednesday, December 14, 2016 1:11:51 AM CET Holger Dengler wrote: > The Eberspaecher Flexcard PMC II offers a Flexray network synchronized > counter with a selectable resolution of 1us, 100ns or 10ns. Add basic > support for the timestamp counter with 1us resolution, which is the > standard Flexray bus resolution. > > Signed-off-by: Benedikt Spranger <b.spran...@linutronix.de> > Signed-off-by: Holger Dengler <deng...@linutronix.de> > cc: Arnd Bergmann <a...@arndb.de> > cc: Greg Kroah-Hartman <gre...@linuxfoundation.org> >
Have you tried fitting this in the drivers/ptp/ framework rather than having your own posix clock for it? No idea if that works, it's just a thought I had. Arnd