On Wednesday, December 14, 2016 1:11:51 AM CET Holger Dengler wrote:
> The Eberspaecher Flexcard PMC II offers a Flexray network synchronized
> counter with a selectable resolution of 1us, 100ns or 10ns. Add basic
> support for the timestamp counter with 1us resolution, which is the
> standard Flexray bus resolution.
> 
> Signed-off-by: Benedikt Spranger <b.spran...@linutronix.de>
> Signed-off-by: Holger Dengler <deng...@linutronix.de>
> cc: Arnd Bergmann <a...@arndb.de>
> cc: Greg Kroah-Hartman <gre...@linuxfoundation.org>
> 

Have you tried fitting this in the drivers/ptp/ framework rather
than having your own posix clock for it?

No idea if that works, it's just a thought I had.

        Arnd