On 03/10/2017 12:13 PM, Russell King - ARM Linux wrote:
Version 5 gives me no v4l2 controls exposed through the video device
interface.

Just like with version 4, version 5 is completely useless with IMX219:

imx6-mipi-csi2: LP-11 timeout, phy_state = 0x00000200
ipu1_csi0: pipeline start failed with -110
imx6-mipi-csi2: LP-11 timeout, phy_state = 0x00000200
ipu1_csi0: pipeline start failed with -110
imx6-mipi-csi2: LP-11 timeout, phy_state = 0x00000200
ipu1_csi0: pipeline start failed with -110


If it's too difficult to get the imx219 csi-2 transmitter into the
LP-11 state on power on, perhaps the csi-2 receiver can be a little
more lenient on the transmitter and make the LP-11 timeout a warning
instead of error-out.

Can you try the attached change on top of the version 5 patchset?

If that doesn't work then you're just going to have to fix the bug
in imx219.

Steve
diff --git a/drivers/staging/media/imx/imx6-mipi-csi2.c b/drivers/staging/media/imx/imx6-mipi-csi2.c
index d8f931e..720bf4d 100644
--- a/drivers/staging/media/imx/imx6-mipi-csi2.c
+++ b/drivers/staging/media/imx/imx6-mipi-csi2.c
@@ -224,11 +224,8 @@ static int csi2_dphy_wait_stopstate(struct csi2_dev *csi2)
 
 	ret = readl_poll_timeout(csi2->base + CSI2_PHY_STATE, reg,
 				 (reg & mask) == mask, 0, 500000);
-	if (ret) {
-		v4l2_err(&csi2->sd, "LP-11 timeout, phy_state = 0x%08x\n", reg);
-		return ret;
-	}
-
+	if (ret)
+		v4l2_warn(&csi2->sd, "LP-11 timeout, phy_state = 0x%08x\n", reg);
 	return 0;
 }
 