On 03/24/2017 06:20 PM, Akshay Bhat wrote: > Hi Marc, > > On 03/17/2017 05:10 PM, Akshay Bhat wrote: >> This patch adds support for the Holt HI-311x CAN controller. The HI311x >> CAN controller is capable of transmitting and receiving standard data >> frames, extended data frames and remote frames. The HI311x interfaces >> with the host over SPI. >> >> Datasheet: www.holtic.com/documents/371-hi-3110_v-rev-jpdf.do >> >> Signed-off-by: Akshay Bhat <[email protected]> >> --- >> > > If there are no further review comments can this series be applied to > can-next or does it need to wait for the next kernel release cycle (4.13)?
The driver doesn't check if the workqueue allocation is successfull,
I've squashed this patch:
> diff --git a/drivers/net/can/spi/hi311x.c b/drivers/net/can/spi/hi311x.c
> index ff4bb40d855e..170e8e3971b2 100644
> --- a/drivers/net/can/spi/hi311x.c
> +++ b/drivers/net/can/spi/hi311x.c
> @@ -780,20 +780,24 @@ static int hi3110_open(struct net_device *net)
>
> priv->wq = alloc_workqueue("hi3110_wq", WQ_FREEZABLE | WQ_MEM_RECLAIM,
> 0);
> + if (!priv->wq) {
> + ret = -ENOMEM;
> + goto out_free_irq;
> + }
> INIT_WORK(&priv->tx_work, hi3110_tx_work_handler);
> INIT_WORK(&priv->restart_work, hi3110_restart_work_handler);
>
> ret = hi3110_hw_reset(spi);
> if (ret)
> - goto out_free_irq;
> + goto out_free_wq;
>
> ret = hi3110_setup(net);
> if (ret)
> - goto out_free_irq;
> + goto out_free_wq;
>
> ret = hi3110_set_normal_mode(spi);
> if (ret)
> - goto out_free_irq;
> + goto out_free_wq;
>
> can_led_event(net, CAN_LED_EVENT_OPEN);
> netif_wake_queue(net);
> @@ -801,11 +805,12 @@ static int hi3110_open(struct net_device *net)
>
> return 0;
>
> -out_free_irq:
> + out_free_wq:
> + destroy_workqueue(priv->wq);
> + out_free_irq:
> free_irq(spi->irq, priv);
> hi3110_hw_sleep(spi);
> -
> -out_close:
> + out_close:
> hi3110_power_enable(priv->transceiver, 0);
> close_candev(net);
> mutex_unlock(&priv->hi3110_lock);
Marc
--
Pengutronix e.K. | Marc Kleine-Budde |
Industrial Linux Solutions | Phone: +49-231-2826-924 |
Vertretung West/Dortmund | Fax: +49-5121-206917-5555 |
Amtsgericht Hildesheim, HRA 2686 | http://www.pengutronix.de |
signature.asc