On 17/04/17 06:33, Viresh Kumar wrote:
> On 13-04-17, 14:43, Sudeep Holla wrote:
>> Interesting. My understand of power domain and in particular power
>> domain performance was that it would control both. The abstract number
>> you introduce would hide clocks and regulators.
>>
>> But if the concept treats it just as yet another regulator, we do we
>> need these at all. Why don't we relate this performance to regulator
>> values and be done with it ?
>>
>> Sorry if I am missing to understand something here. I would look this as
>> replacement for both clocks and regulators, something similar to ACPI
>> CPPC. If not, it looks unnecessary to me with the information I have got
>> so far.
> 
> I kind of answered that in the other email.
> 
> Some background may be good here. So Qcom tried to solve all this with virtual
> regulators, but the problem was that they need to talk in terms of integer
> values (1, 2, 3..) and not voltages and so they can't use the regulator
> framework straight away. And so we are doing all this.
> 

Was it posted externally ? Was there any objections for that approach ?
IMO that's better approach but if I am late to the party, I would like
to read through the discussions that happened on it(if any)

-- 
Regards,
Sudeep

Reply via email to