Hi,

On Fri, Apr 14, 2017 at 08:25:56PM +0200, H. Nikolaus Schaller wrote:
> Currently, the twl4030 charger defines its own max_current by directly
> creating sysfs nodes. It should use the input_current_limit property
> which is e.g. used by the bq24257 driver.
> 
> This patch adds the input_current_property with the same semantics as
> the max_current property. The code to manage the max_current property
> is removed by a separate patch.
> 
> Signed-off-by: H. Nikolaus Schaller <[email protected]>

Thanks, queued.

-- Sebastian

Attachment: signature.asc
Description: PGP signature

Reply via email to