From: Ravikumar Kattekola <[email protected]>

As per recent TRM, PBIAS cell on omap5 devices supports
3.3v and not 3.0v as documented earlier.

Update PBIAS regulator max voltage to match this.

Document reference:
SWPU249AF - OMAP543x Technical reference manual August 2016

Signed-off-by: Ravikumar Kattekola <[email protected]>
Signed-off-by: Sekhar Nori <[email protected]>
Signed-off-by: Kishon Vijay Abraham I <[email protected]>
---
 arch/arm/boot/dts/omap5.dtsi | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/arch/arm/boot/dts/omap5.dtsi b/arch/arm/boot/dts/omap5.dtsi
index eaff2a5751dd..e6af460ee301 100644
--- a/arch/arm/boot/dts/omap5.dtsi
+++ b/arch/arm/boot/dts/omap5.dtsi
@@ -194,7 +194,7 @@
                                                pbias_mmc_reg: pbias_mmc_omap5 {
                                                        regulator-name = 
"pbias_mmc_omap5";
                                                        regulator-min-microvolt 
= <1800000>;
-                                                       regulator-max-microvolt 
= <3000000>;
+                                                       regulator-max-microvolt 
= <3300000>;
                                                };
                                        };
                                };
-- 
2.11.0