On Fri, Jan 26, 2018 at 10:07 PM, Benoît Thébaudeau <[email protected]> wrote: > The eSDHC does not work properly if the SION bit is not set for the > bidirectional CMD signal, whatever the eSDHC instance and the selected > pad. Therefore, setting SION is mandatory for all eSDHC CMD ports. Do > this for MX25_PAD_*__SD*_CMD in imx25-pinfunc.h in order to enforce this > behavior for all boards. > > This had already been done for eSDHC1, but not for eSDHC2. Also, define > MX25_PAD_FEC_MDC__SDHC2_CMD so that all the possible cases are covered > from now on. > > Signed-off-by: Benoît Thébaudeau <[email protected]>
Thanks for the fix: Reviewed-by: Fabio Estevam <[email protected]>