From: Mike Leach <[email protected]>

[ Upstream commit eeedc5421dd3b51de73e6106405c5c77f920f281 ]

Corrected to get the port numbering to allow programmable replicator driver
to operate correctly.

By convention, CoreSight devices number ports, not endpoints in
the .dts files:-

port {
     reg<N>
     endpoint {
     }
}

Existing code read endpoint number - always 0x0, rather than the correct
port number.

Signed-off-by: Mike Leach <[email protected]>
Signed-off-by: Mathieu Poirier <[email protected]>
Signed-off-by: Greg Kroah-Hartman <[email protected]>
Signed-off-by: Sasha Levin <[email protected]>
---
 drivers/hwtracing/coresight/of_coresight.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/hwtracing/coresight/of_coresight.c 
b/drivers/hwtracing/coresight/of_coresight.c
index 629e031b7456..09142e99e915 100644
--- a/drivers/hwtracing/coresight/of_coresight.c
+++ b/drivers/hwtracing/coresight/of_coresight.c
@@ -149,7 +149,7 @@ struct coresight_platform_data 
*of_get_coresight_platform_data(
                                continue;
 
                        /* The local out port number */
-                       pdata->outports[i] = endpoint.id;
+                       pdata->outports[i] = endpoint.port;
 
                        /*
                         * Get a handle on the remote port and parent
-- 
2.14.1