Enable/check sensor after enabling monitoring.

Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnier...@samsung.com>
---
 drivers/thermal/qoriq_thermal.c | 6 +++---
 1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/thermal/qoriq_thermal.c b/drivers/thermal/qoriq_thermal.c
index cdd6f59..2695021 100644
--- a/drivers/thermal/qoriq_thermal.c
+++ b/drivers/thermal/qoriq_thermal.c
@@ -242,13 +242,13 @@ static int qoriq_tmu_probe(struct platform_device *pdev)
                goto err_tmu;
        }
 
-       thermal_zone_device_toggle(data->tz, true);
-       thermal_zone_device_check(data->tz);
-
        /* Enable monitoring */
        site |= 0x1 << (15 - data->sensor_id);
        tmu_write(data, site | TMR_ME | TMR_ALPF, &data->regs->tmr);
 
+       thermal_zone_device_toggle(data->tz, true);
+       thermal_zone_device_check(data->tz);
+
        return 0;
 
 err_tmu:
-- 
1.9.1