On 20.04.2018 17:23, Arnd Bergmann wrote: > On Thu, Apr 19, 2018 at 8:51 AM, Baolin Wang <baolin.w...@linaro.org> wrote: >> The read_persistent_clock() uses a timespec, which is not year 2038 safe >> on 32bit systems. On parisc architecture, we have implemented generic RTC >> drivers that can be used to compensate the system suspend time, but the >> RTC time can not represent the nanosecond resolution, so this patch just >> converts to read_persistent_clock64() with timespec64. >> >> Signed-off-by: Baolin Wang <baolin.w...@linaro.org> > > I have created the exact same patch a while ago but never submitted that. > > If the parisc maintainers want to apply yours with my Ack, that > would be appreciated. > > Acked-by: Arnd Bergmann <a...@arndb.de>
Thanks, I'll take it through the parisc git tree. Helge