Hi Fabio,
Thanks for the review.

On Mon 23 Apr 2018 at 14:11, Fabio Estevam wrote:
Hi Rui,

On Thu, Apr 19, 2018 at 8:00 AM, Rui Miguel Silva <rui.si...@linaro.org> wrote:

+Optional Properties:
+- powerdown-gpios: reference to the GPIO connected to the powerdown pin, + if any. This is an active high signal to the OV2680.

I looked at the OV2680 datasheet and I see a pin called XSHUTDN, which has
the following description:

XSHUTDN: reset and power down (active low with internal pull down resistor)

So it should be active low, not active high.

Yes, you are correct, I will fix this, and the dts entry.

Thanks.

---
Cheers,
        Rui



Reply via email to