On 04/24/2018 09:09 AM, Alexandre Belloni wrote:
> Some MDIO busses will error out when trying to read a phy address with no
> phy present at that address. In that case, probing the bus will fail
> because __mdiobus_register() is scanning the bus for all possible phys
> addresses.
> 
> In case MII_PHYSID1 returns -EIO or -ENODEV, consider there is no phy at
> this address and set the phy ID to 0xffffffff which is then properly
> handled in get_phy_device().
> 
> Suggested-by: Andrew Lunn <and...@lunn.ch>
> Signed-off-by: Alexandre Belloni <alexandre.bell...@bootlin.com>

Reviewed-by: Florian Fainelli <f.faine...@gmail.com>
-- 
Florian

Reply via email to