On Thu, 2018-06-28 at 16:08 +0200, Daniel Lezcano wrote:
> > +** System Timer (SYST)
> > +
> > +Required properties:
> > +- compatible: Should contain
> > +   * "mediatek,mt6765-systimer" for MT6765 compatible timers
> > +- reg: Should contain the location and length for system timer registers.
> > +- clocks: System timer is drived by system clock.
> > +
> > +Examples:
> > +
> > +   systimer@10017000 {
> > +           compatible = "mediatek,mt6765-systimer";
> 
> why not "mediatek,mt6765-timer" ? for consistency.
> 
Hi Daniel,

The original thought is to remind user to notice that different timer
will be used.

However it looks more clean if we use consistent name.

Will fix it in v4.

> > +           reg = <0 0x10017000 0 0x1000>;
> > +           interrupts = <GIC_SPI 194 IRQ_TYPE_LEVEL_HIGH>;
> > +           clocks = <&system_clk>;
> >     };
> > 
> 
> 

Thanks.
Stanley Chu

Reply via email to